How Can We Help?
Optex LX-402/802N to IP camera
This is a guide on how to physically install the LX-402/802N IR detector and connect it to your IP camera.
What you need:
- IR detector
- Cable for signal and power (included in the delivery)
- Sugar Bite
- Power adapter (12 V DC)
Step 1. Attach the IR detector and connect cables
- Unscrew the screw at the bottom and carefully open the casing.
- Attach the IR detector to the wall with the included screws or via a wall/ceiling mount. We recommend a height of 2 - 2.5 metres above the ground for best results.
- Turn "Photocell" to "DAY" to enable round-the-clock detection
- Thread the included 4-wire cord through the hole on the back
- Connect green wire to "COM" and yellow wire to "N.C"
- Connect red wire to + and black wire to -
- Press the black sponge into the cable gland to seal against moisture
- Close the lid and then screw in the screw again
Step 2. Connect power and IP camera
- Connect the signal wires from the IR detector to the camera's "ALARM IN" and "GND" using a sugar cube.
- Connect power (12 V DC) from the supplied power adapter to the detector using a sugar cube. Connect red to red and black to black.
- Weatherproof the connections in a suitable junction box.
Step 3. Test the detector
- Check that the detector is connected to power
- Walk in front of the detector, if everything works properly, a red LED will flash